Free Ball Float Steam Trap (GACS41H)

Model NO.: GACS41H
Size: 1/2"-6"
Medium: Steam
Tma: 350 Deg C
Usage: Drain
Application: Steam Equipment/Steam Pipelines
Trademark: GOOLE, OEM
Transport Package: Carton, Plywood Case
Specification: ISO 9001
Origin: China(Mainland)
HS Code: 8481804090

CS41 Free Ball float Steam Trap

 
Brief Introduction.
 
Advantages.

1.Continues discharging saturation condensed water without accumulation, and so get the maximum thermal efficiency.
2.When steam pressure changes, the ball float can adjust the opening of valve seat without influence, and so it is stable.
3.With automatic and manual releaser, and so its exhaust performance is good without airlock and working is smooth without noise.
 
Working Principle.

a.When the device starts up,as the temperature of steam trap is low,sylphon temperature sensing element contracts,air vent hole (A) open,discharging the air inside continiously,realizing quick opening.

Free Ball Float Steam Trap (GACS41H)
b.
When condensed water flow into steam trap,air is discharged from air vent(A) automatically,float ball rises with level of condensed water,then condensed water is discharged from drain hole(B).

Free Ball Float Steam Trap (GACS41H)
c.When hot condensed water and steam flow into steam trap,the liquid in sylphon expands under high temperature,air vent(A) close accordingly,float ball rise and down with the level of condensed water,discharging hot condensed water.

Free Ball Float Steam Trap (GACS41H)
d.When condensed water stop flowing into the steam trap,float ball falls with level of condensed water and close the drain hole(B),as the drain hole is always under the level of condensed water,forming water sealing,no steam leaking.

Free Ball Float Steam Trap (GACS41H)
 
Application.

By automation, speediness and continuing features, this valve is used for the steam heating equipment, condensation water recovery system and the place where needs removing condensation water at quick speed, and so stop steam leakage effectively and obtain optimum heating.
 
 
Main Technical Parameters and Indexes of Performance.
 
Mini Working Pressure 0.01Mpa Maxi allowable temperature for cast steel 42 5
Mini Working Pressure 0.01Mpa Maxi allowable temperature for cast steel 42 5
Mini degree of super cooling 0 Maxi allowable temperature for stainless steel 525
Leakage rate with loading 0 Working Medium Saturated vapor, condensed water
Maxi allowable rate of back pressure 80% Exhaust plant Stainless steel / alloy
 
Material of Main Component.
 
Valve body, cap WCB / 304
Valve seat 2Cr13 / 304
Floating ball Stainless steel
Filter Stainless steel
 
Main External Dimensions.
 
 Free Ball Float Steam Trap (GACS41H)
 
Producnt model DN Conjunction method Max.allowable temp. Material of valve body External dimension (mm)
L H1 H2 W
A series
Free Ball floating
Steam Trap
15 Internal thread 350 WCB 120 82 89 84
20 Internal thread 350 WCB 120 82 89 84
25 Internal thread 350 WCB 120 84 95 84
B series
Free Ball float
Steam Trap
15 Internal thread 350 WCB 150 84 114 114
20 Internal thread 350 WCB 150 84 114 114
25 Internal thread 350 WCB 150 86.5 116.5 114
32 Internal thread 350 WCB 155 98.5 104.5 114
40 Internal thread 350 WCB 155 98.5 104.5 114
50 Internal thread 350 WCB 210 98.5 104.5 114
C series
Free Ball float
Steam Trap
15 Flange 350 WCB 195 94.5 107 132
20 Flange 350 WCB 195 97 104.5 132
25 Flange 350 WCB 215 101.5 111.5 140
D series
Free Ball float
Steam Trap
25 Flange 350 WCB 270 102.5 151 180
32 Flange 350 WCB 270 109 154.5 180
40 Flange 350 WCB 280 112 170 184
50 Flange 350 WCB 290 117 175 195
F series
Free Ball float
Steam Trap
50 Flange 350 WCB 410 132 129 270
65 Flange 350 WCB 410 139.5 136.5 270
80 Flange 350 WCB 430 148 313 275
100 Flange 350 WCB 430 158 323 280
G series
Free Ball float
Steam Trap
80 Flange 350 WCB 550 147 331 335
100 Flange 350 WCB 550 147 331 335
125 Flange 350 WCB 550 169.5 353.5 335
150 Flange 350 WCB 550 169.5 353.5 335

Set Rule for Guide Rail, Guide Rail Locator, Location Rule of Guide Rail, Locating Rule of Guide Rail


We carry high quality Set Rule for Guide Rail for all major elevator and escalator brands

for OTIS Elevators, ThyssenKrupp Elevators, Schindler Elevators, KONE Elevators, Mitsubishi Elevators, Fujitec Elevators, Hitachi Elevators, Toshiba Elevators, Fuji Elevators, Express Elevators, Sigma Elevators, LG Elevators, Hyundai Elevators, BLT Elevators, CANNY Elevators, SJEC Elevators, KOYO Elevators



Set Rule for Guide Rail

Set Rule for Guide Rail, Guide Rail Locator, Location Rule of Guide Rail, Locating Rule of Guide Rail

CEP Elevator Products ( China ) Co., Ltd. , https://www.elevatorcomponent.nl

Posted on