Power Saving Wet FRP Cooling Tower

Model NO.: SWJY-CT037
Noise Level: Ultra Low
Application Fields: Air Conditioning
Certification: ISO, CE
Condition: New
Brand: Swjy
Main Material: FRP GRP Fiber Reinforce Plastic
Shape: Round, Square
Type: Standard, Low Noise, High Temperature, Industrial
After-Sales Service Provided: Overseas Service Center Available
Place of Origin: Hebei, China (Mainland)
Packaging Details: According to Customers Requirements.
Delivery Detail: Within 30 Days After Receive Order
FRP Colour: All Colour
Net/Operation Weight: 500kg-100000kg
Trademark: SWJY
Transport Package: According to Customers Requirements.
Specification: complete
Origin: Hebei, China
HS Code: 84195000
Model NO.: SWJY-CT037
Noise Level: Ultra Low
Application Fields: Air Conditioning
Certification: ISO, CE
Condition: New
Brand: Swjy
Main Material: FRP GRP Fiber Reinforce Plastic
Shape: Round, Square
Type: Standard, Low Noise, High Temperature, Industrial
After-Sales Service Provided: Overseas Service Center Available
Place of Origin: Hebei, China (Mainland)
Packaging Details: According to Customers Requirements.
Delivery Detail: Within 30 Days After Receive Order
FRP Colour: All Colour
Net/Operation Weight: 500kg-100000kg
Trademark: SWJY
Transport Package: According to Customers Requirements.
Specification: complete
Origin: Hebei, China
HS Code: 84195000
Power Saving Wet FRP Cooling Tower

Introductions:
FRP counter & cross flow water cooling tower is designed to economic and save water, it is a huge advance in industry. We take Fiber reinforced plastic as the materials of cooling tower. The standard water cooling tower can afford the highest temperature is 60°C. If the temperature is higher than 60°C,we suggest you choose the High temperature cooling tower which can afford 100°C.
 Power Saving Wet FRP Cooling Tower



Product features:
1 Excellent performance
2 High Quality
3 Environmental protection and energy conservation
4 Good shape with small outside size, light weight
5 Low Noise: The lowest noise blower and unique noise elimination technology is adopted to reduce the noise to a minimum level.
6 Type: Standard, low noise and High temperature, industrial type to meet customer's needs.
Simple operation and maintenance: CTNC intelligent control system is adopted to realize labor free management
7 Cooling capacity ranges from 3 to 780 M3/h, relevant refrigeration ton is from 5 to1000.
 Power Saving Wet FRP Cooling Tower


Structures and working principle:
Optimum structure: All structures can be treated with rust-removing, hot dipped galvanized Steel. All can bear corrosion, have high strength, be easily assembled and have elegant surface.
    1 Body: The cooling tower body is made of stabilization material---FRP, which is anti-aging, anti-corrosion, resisting ultraviolet radiation, without fading and distortion. It has long service life.
    2 Fan: Use special fan with variable section, twist and pitching blade. The fan Works at an equal speed, a low self moving pressure, an energy-saving use and a low noise. Fixing angle of blade is changeable to meet the work demands and improve the efficiency. The angles of all fans are regulative and axial-flow, which made of advanced engineering plastics.
    3 Motor: All the motors (380V/3φ /50Hz mostly) of the cooling tower are sealed, which can be used in the severe weather and circumstances.
    4 Fill: The fill is made of polyvinyl chloride which is hard and heat-resisting, be able to be extended the time and space of heat exchange. The temperature in the water is up to 54. And the special structure enables the water to touch the fill in the biggest area with low air resistance. The energy exchanging efficiency is very high.
    5 Rotating pipe model which is made of FRP.
6 Brackets: All steel structure brackets are galvanized and corrosion resistant. The usage life is twice longer compared with similar products.
    7 The casing and water plate of the cooling tower are made of fiberglass, which will not be corroded, and no painting is needed. They can be used for a long time with very low maintenance cost.


Power Saving Wet FRP Cooling Tower


 Reference specification  round counter flow cooling tower CDBNL3 series
Type T=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h) Dimension (mm)  
air volume (m3/h)
 Fan diameter
(mm)
 
Motor
power
(kw)
Weight
(kg)
Water pressure
104pa
Noise
Db(A)
Diameter
Dm
t=5ºC t=8ºC t=5ºC t=8ºC total height maximum diameter Self
-
weight
Running
weight
Dm 10m 16m
CDBNL3-12
CDBNL3-20
CDBNL3-30
CDBNL3-40
12
20
30
40
9
15
22
30
15
24
35
46
10
17
27
34
2972
3062
3281
3781
1600
2000
2400
2400
7200
12400
18000
21500
700
800
1200
1200
0.6
0.8
0.8
1.1
306
330
546
618
584
644
1100
1258
1..90
2.00
2.21
2.60
50.0
50.0
51.0
51.0
37.1
36.3
39.5
39.5
33.5
32.6
35.9
35.9
1.5
1.5
1.8
1.8
CDBNL3-50 CDBNL3-60 CDBNL3-70 CDBNL3-80 50
60
70
80
37
44
51
61
57
68
79
92
44
51
60
70
3816
4066
4153
4403
2800
2800
3300
3300
28000
32300
39200
43400
1400
1400
1600
1600
1.5
1.5
2.2
2.2
756
950
998
1083
1640
1752
2272
2451
2.65
2.90
2.78
2.03
51.0
52.0
52.0
52.5
40.7
41.7
43.0
43.5
37.1
38.1
39.0
39.5
2.1
2.1
2.5
2.5
CDBNL3-100
CDBNL3-125
CDBNL3-150
CDBNL3-175
100
125
150
175
74
92
112
131
114
142
171
200
86
108
129
150
4410
4690
4765
5015
3900
3900
4600
4600
56000
67200
84000
94300
1800
1800
2400
2400
3.0
4.0
4.0
5.5
1230
1320
2045
2182
3322
3422
4475
4808
2.86
3.15
2.90
3.15
53.0
54.0
54.0
55.0
46.0
46.7
47.5
48.5
42.0
43.4
44.1
45.1
3.0
3.0
3.6
3.6
CDBNL3-200
CDBNL3-250
CDBNL3-300
CDBNL3-350
200
250
300
350
153
186
225
267
231
283
334
395
180
215
260
304
5194
5444
5713
5963
5700
5700
6400
6400
112000
134300
168000
187400
2800
2800
3400
3400
5.5
7.5
7.5
11.0
2663
2875
4132
4434
6123
6892
9805
10479
3.01
3.26
3.50
3.75
55.0
56.0
56.0
56.5
49.6
50.6
51.8
52.3
46.3
47.3
48.5
49.0
4.2
4.2
5.0
5.0
CDBNL3-400
CDBNL3-450
CDBNL3-500
CDBNL3-600
400
450
500
600
301
343
375
454
455
514
576
680
341
387
427
516
6269
6519
6890
7390
7400
7400
8200
8200
224000
242000
280000
302200
3800
3800
4200
4200
11.0
11.0
15.0
18.5
4995
5341
6612
7414
12782
14160
17102
12904
3.60
3.85
3.70
4.20
57.0
57.0
57.0
58.0
53.8
53.8
55.0
56.0
50.7
50.7
51.9
52.4
5.9
5.9
6.6
6.6
Reference specification Square cross-flow cooling tower AHBLD, HBLCD series
Type T=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h) Dimension(mm) air volume (m3/h) Fan diameter
(mm)
Motor installed capacity
(Kw)
Weight
(t)
Noise 
db(A)
t=5ºC t=8ºC t=5ºC t=8ºC length width Height self-weight Running
weight
AHBLD
HBLD-300
300 225 343 255 7250 3810 4514 167000 3400 7.5 5.85 13.38 59.0
AHBLD
HBLD-500
500 377 576 427 8030 4650 5320 260000 4200 11.0 9.20 17.24 61.5
AHBLD
HBLD-700
700 528 803 596 8930 6640 5320 370000 5000 18.5 12.95 26.05 62.6
AHBLCD
HBLCD-300
300 225 343 255 10650 3810 6230 167000 3400 7.5 7.05 14.18 52.5
AHBLCD
HBLCD-500
500 377 576 427 11640 4650 7030 26000 4200 11.0 10.8 18.84 53.7
AHBLCD
HBLCD-700
700 528 803 596 12540 6640 7180 37000 5000 18.5 14.75 26.81 54.5
Reference specification Square counter flow cooling tower
DFN series
Type T=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h) Dimension (mm) air volume (m3/h) Fan   diameter
(mm)
Motor
power 
(kw)
Weight
(t)
intake pressure 104pa Noise 
Db(A)
diameter Dm
t=5ºC t=8ºC t=5ºC t=8ºC total height widthB self-weight Running
weight
Dm 10m 16m
DFNL-100
DFNDP-100
DFNGP-100
100 74.4 118.7 86 3830
4390
4690
2600 62000 1800 3.0/1.5 1.9
2.16
2.46
2.44
3.78
5.7
6.2 59 52 47 3.02
DFNL-150
DFNDP-150
DFNGP-150
150 109.8 175.1 126.9 4050
4670
4970
3000 84000 2400 4.0/2.0 2.6
2.91
3.31
3.32
5.07
7.63
6.3 60.5 54 50.6 3.47
DFNL-200
DFNDP-200
DFNGP-200
200 148.9 237.4 172.1 4340
4960
5260
3600 115000 2800 5.5/2.7 3.1
3.55
4.44
4.13
6.66
10.56
6.5 62 55.6 52.3 4.15
DFNL-300
DFNDP-300
DFNGP-300
300 224.9 350.5 258.3 5010
5690
5990
4300 158600 3400 7.5/3.7 4.4
5.04
5.91
5.88
9.48
14.79
5.8 62 57.8 54.5 4.94
DFNL-400
DFNDP-400
DFNGP-400
400 299.9 476.4 344.4 5300
6040
6340
4800 213000 3800 11/5.5 5.3
6.1
6.96
7.14
10.57
18.02
6 62.5 58.8 55.7 5.51
DFNL-500
DFNDP-500
DFNGP-500
500 374.9 584.3 430.4 5900
6700
7000
5300 265000 3800 15/7.5 6.6
7.58
8.64
8.85
13.11
19.7
6.4 62.5 59.3 56.2 6.08
DFNL-600
DFNDP-600
DFNGP-600
600 448.5 698.9 514.9 6140
6980
7280
6000 317500 4200 15/7.5 8.42
9.68
10.85
11.3
34.56
28.13
6.5 62.5 60.5 57.4 6.88
DFNL-750
DFNDP-750
DFNGP-750
750 561.7 875.3 644.9 6440
7290
7590
6800 400000 4200 22/11 10.8
12.41
13.84
14.5
23.51
36.04
6.8 63 61.4 58.4 7.79
DFNL-900
DFNDP-900
DFNGP-900
900 673.4 1049.5 773.2 6950
7900
8200
7300 490000 4700 30/15 12.5
14.36
15.93
16.76
25.46
38.13
7 63.8 62.9 60 8.36
DFNL-1050
DFNDP-1050
DFNGP-1050
1050 786.6 1225.9 903.1 7150
8100
8400
7800 556000 4700 30/15 15.1
17.22
18.94
19.97
31.82
48.14
7 64.6 63.1 53.9 8.93
Reference specification Non-filling spraying cooling tower YJGWL-800~5000 series
Type T=28ºC cooling water flow (m3/h) Size                                                (mm) At= 10t Fixing atomizer(set) Fan diameter
(mm)
whole pressure air volume (m3/h) Motor power  KW Water inlet pressure Mpa Inlet pipe   mm atmospheric pressure Pa self-weight  t Running weight  t Noise  Db    (A)
  t=6 t=10 t=25 L W H H1 H2 H3 Dm
YJGWL-800 1000 800 650 8400 8400   3000 4600 2000 16 4700 102 6.2 x106 30   Φ 300 x 2 11.1 17.6 ≤70
YJGWL-1000 1200 1000 800 9400 9400 10300 3000 5100 2200 20 4700 115 7.8 x106 37   Φ 300 x 2 13.5 21.2 ≤70
YJGWL-1200 1500 1200 1000 10400 10400 11100 3600 5100 2400 24 5460 105 9.3 x10s 45   Φ350 x 2 16.9 26.6 ≤70
VJGWL-1500 2000 1500 1200 11200 11200 11900 4200 5100 2600 30 6000 120 12.0x106 55 0.1 Φ 350 x 2 18.2 29.1 ≤70
YJGWL-2000 2500 2000 1500 13000 13000 13700 4600 6100 3000 42 7000 123 16.0x10s 90 - Φ 400x2 100400 24.7 40.1 ≤70
YJGWL-2500 3000 2500 2000 14600 14600 14200 4600 6100 3500 48 8000 135 20x105 110 0.15 Φ 450 x 2 28.6 47.1 ≤70
VJGWL-3000 3500 3000 2500 16000 16000 14400 4600 6100 3700 64 8530 130 24x105 110   Φ 500 x 2 37.8 52.2 ≤70
YJGWL-3500 4000 3500 3000 17000 17000 16100 5000 7100 4000 72 8530 135 27.3 x105 132   Φ 600 x 2 42.5 56.3 ≤70
YJGWL-4000 5000 4000 3500 18000 18000 16500 5000 7100 4400 80 9140 138 32.3 x10s 132   4> 600 x 2 50.1 68 ≤70
YJGWL-5000 6000 5000 4000 20000 20000 17700 5600 7100 5000 100 10060 1 40.6x105 185   Φ 700 x 2 61 80.7 ≤70
Power Saving Wet FRP Cooling Tower

Introductions:
FRP counter & cross flow water cooling tower is designed to economic and save water, it is a huge advance in industry. We take Fiber reinforced plastic as the materials of cooling tower. The standard water cooling tower can afford the highest temperature is 60°C. If the temperature is higher than 60°C,we suggest you choose the High temperature cooling tower which can afford 100°C.
 Power Saving Wet FRP Cooling Tower



Product features:
1 Excellent performance
2 High Quality
3 Environmental protection and energy conservation
4 Good shape with small outside size, light weight
5 Low Noise: The lowest noise blower and unique noise elimination technology is adopted to reduce the noise to a minimum level.
6 Type: Standard, low noise and High temperature, industrial type to meet customer's needs.
Simple operation and maintenance: CTNC intelligent control system is adopted to realize labor free management
7 Cooling capacity ranges from 3 to 780 M3/h, relevant refrigeration ton is from 5 to1000.
 Power Saving Wet FRP Cooling Tower


Structures and working principle:
Optimum structure: All structures can be treated with rust-removing, hot dipped galvanized Steel. All can bear corrosion, have high strength, be easily assembled and have elegant surface.
    1 Body: The cooling tower body is made of stabilization material---FRP, which is anti-aging, anti-corrosion, resisting ultraviolet radiation, without fading and distortion. It has long service life.
    2 Fan: Use special fan with variable section, twist and pitching blade. The fan Works at an equal speed, a low self moving pressure, an energy-saving use and a low noise. Fixing angle of blade is changeable to meet the work demands and improve the efficiency. The angles of all fans are regulative and axial-flow, which made of advanced engineering plastics.
    3 Motor: All the motors (380V/3φ /50Hz mostly) of the cooling tower are sealed, which can be used in the severe weather and circumstances.
    4 Fill: The fill is made of polyvinyl chloride which is hard and heat-resisting, be able to be extended the time and space of heat exchange. The temperature in the water is up to 54. And the special structure enables the water to touch the fill in the biggest area with low air resistance. The energy exchanging efficiency is very high.
    5 Rotating pipe model which is made of FRP.
6 Brackets: All steel structure brackets are galvanized and corrosion resistant. The usage life is twice longer compared with similar products.
    7 The casing and water plate of the cooling tower are made of fiberglass, which will not be corroded, and no painting is needed. They can be used for a long time with very low maintenance cost.


Power Saving Wet FRP Cooling Tower


 Reference specification  round counter flow cooling tower CDBNL3 series
Type T=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h) Dimension (mm)  
air volume (m3/h)
 Fan diameter
(mm)
 
Motor
power
(kw)
Weight
(kg)
Water pressure
104pa
Noise
Db(A)
Diameter
Dm
t=5ºC t=8ºC t=5ºC t=8ºC total height maximum diameter Self
-
weight
Running
weight
Dm 10m 16m
CDBNL3-12
CDBNL3-20
CDBNL3-30
CDBNL3-40
12
20
30
40
9
15
22
30
15
24
35
46
10
17
27
34
2972
3062
3281
3781
1600
2000
2400
2400
7200
12400
18000
21500
700
800
1200
1200
0.6
0.8
0.8
1.1
306
330
546
618
584
644
1100
1258
1..90
2.00
2.21
2.60
50.0
50.0
51.0
51.0
37.1
36.3
39.5
39.5
33.5
32.6
35.9
35.9
1.5
1.5
1.8
1.8
CDBNL3-50 CDBNL3-60 CDBNL3-70 CDBNL3-80 50
60
70
80
37
44
51
61
57
68
79
92
44
51
60
70
3816
4066
4153
4403
2800
2800
3300
3300
28000
32300
39200
43400
1400
1400
1600
1600
1.5
1.5
2.2
2.2
756
950
998
1083
1640
1752
2272
2451
2.65
2.90
2.78
2.03
51.0
52.0
52.0
52.5
40.7
41.7
43.0
43.5
37.1
38.1
39.0
39.5
2.1
2.1
2.5
2.5
CDBNL3-100
CDBNL3-125
CDBNL3-150
CDBNL3-175
100
125
150
175
74
92
112
131
114
142
171
200
86
108
129
150
4410
4690
4765
5015
3900
3900
4600
4600
56000
67200
84000
94300
1800
1800
2400
2400
3.0
4.0
4.0
5.5
1230
1320
2045
2182
3322
3422
4475
4808
2.86
3.15
2.90
3.15
53.0
54.0
54.0
55.0
46.0
46.7
47.5
48.5
42.0
43.4
44.1
45.1
3.0
3.0
3.6
3.6
CDBNL3-200
CDBNL3-250
CDBNL3-300
CDBNL3-350
200
250
300
350
153
186
225
267
231
283
334
395
180
215
260
304
5194
5444
5713
5963
5700
5700
6400
6400
112000
134300
168000
187400
2800
2800
3400
3400
5.5
7.5
7.5
11.0
2663
2875
4132
4434
6123
6892
9805
10479
3.01
3.26
3.50
3.75
55.0
56.0
56.0
56.5
49.6
50.6
51.8
52.3
46.3
47.3
48.5
49.0
4.2
4.2
5.0
5.0
CDBNL3-400
CDBNL3-450
CDBNL3-500
CDBNL3-600
400
450
500
600
301
343
375
454
455
514
576
680
341
387
427
516
6269
6519
6890
7390
7400
7400
8200
8200
224000
242000
280000
302200
3800
3800
4200
4200
11.0
11.0
15.0
18.5
4995
5341
6612
7414
12782
14160
17102
12904
3.60
3.85
3.70
4.20
57.0
57.0
57.0
58.0
53.8
53.8
55.0
56.0
50.7
50.7
51.9
52.4
5.9
5.9
6.6
6.6
Reference specification Square cross-flow cooling tower AHBLD, HBLCD series
Type T=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h) Dimension(mm) air volume (m3/h) Fan diameter
(mm)
Motor installed capacity
(Kw)
Weight
(t)
Noise 
db(A)
t=5ºC t=8ºC t=5ºC t=8ºC length width Height self-weight Running
weight
AHBLD
HBLD-300
300 225 343 255 7250 3810 4514 167000 3400 7.5 5.85 13.38 59.0
AHBLD
HBLD-500
500 377 576 427 8030 4650 5320 260000 4200 11.0 9.20 17.24 61.5
AHBLD
HBLD-700
700 528 803 596 8930 6640 5320 370000 5000 18.5 12.95 26.05 62.6
AHBLCD
HBLCD-300
300 225 343 255 10650 3810 6230 167000 3400 7.5 7.05 14.18 52.5
AHBLCD
HBLCD-500
500 377 576 427 11640 4650 7030 26000 4200 11.0 10.8 18.84 53.7
AHBLCD
HBLCD-700
700 528 803 596 12540 6640 7180 37000 5000 18.5 14.75 26.81 54.5
Reference specification Square counter flow cooling tower
DFN series
Type T=28ºCcooling water flow
(m3/h)
T=27ºCcooling water flow (m3/h) Dimension (mm) air volume (m3/h) Fan   diameter
(mm)
Motor
power 
(kw)
Weight
(t)
intake pressure 104pa Noise 
Db(A)
diameter Dm
t=5ºC t=8ºC t=5ºC t=8ºC total height widthB self-weight Running
weight
Dm 10m 16m
DFNL-100
DFNDP-100
DFNGP-100
100 74.4 118.7 86 3830
4390
4690
2600 62000 1800 3.0/1.5 1.9
2.16
2.46
2.44
3.78
5.7
6.2 59 52 47 3.02
DFNL-150
DFNDP-150
DFNGP-150
150 109.8 175.1 126.9 4050
4670
4970
3000 84000 2400 4.0/2.0 2.6
2.91
3.31
3.32
5.07
7.63
6.3 60.5 54 50.6 3.47
DFNL-200
DFNDP-200
DFNGP-200
200 148.9 237.4 172.1 4340
4960
5260
3600 115000 2800 5.5/2.7 3.1
3.55
4.44
4.13
6.66
10.56
6.5 62 55.6 52.3 4.15
DFNL-300
DFNDP-300
DFNGP-300
300 224.9 350.5 258.3 5010
5690
5990
4300 158600 3400 7.5/3.7 4.4
5.04
5.91
5.88
9.48
14.79
5.8 62 57.8 54.5 4.94
DFNL-400
DFNDP-400
DFNGP-400
400 299.9 476.4 344.4 5300
6040
6340
4800 213000 3800 11/5.5 5.3
6.1
6.96
7.14
10.57
18.02
6 62.5 58.8 55.7 5.51
DFNL-500
DFNDP-500
DFNGP-500
500 374.9 584.3 430.4 5900
6700
7000
5300 265000 3800 15/7.5 6.6
7.58
8.64
8.85
13.11
19.7
6.4 62.5 59.3 56.2 6.08
DFNL-600
DFNDP-600
DFNGP-600
600 448.5 698.9 514.9

WN series dredging slurry pumps are marine dredging pumps for dredging of river and sea. This type pump is simple and reliable in structure, easy to disassemble and maintain, and adopt high chromium wear-resistant alloy material. It has a long trouble-free life. This series of dredging pumps are single stage single suction horizontal centrifugal pumps. The flow passage of the impeller is wide through the capacity, so it is difficult to block for pumping sand gravel or high plastic clay. It has super strong excavation and suction ability. The WN series dredge pumps is suitable for cutter-suction dredger and trailing suction dredger. It is also used for river sand mining and mining vessels.

Product Feature

1.The structure is simple and reliable, easy to assemble and disassemble and easy to maintain. The front dismantling structure is adopted, and special disassembly tools are equipped to facilitate disassembly and assembly.

2.The performance of dredging is excellent. The flow and head curve of the pump are steep, the suction ability is strong, the ability of passing the pump is good, the change of the distance is more applicable, and the depth of digging and the higher transportation concentration can be reached.

3.Good wear resistance and long life of flow parts. The liners are made of strong wear resistant alloy cast iron, and have high abrasion resistance. Special high chromium alloy cast iron is used for impeller, which is both abrasion resistant and impact resistant.

4.Adopting the advanced hydraulic model, the hydraulic loss is small, the efficiency is high, and the energy consumption is low.

5.The shaft seal is reliable and no leakage. 

WN Series Dredge Slurry Pumps

WN Series Dredge Slurry Pumps,Dredge Slurry Pumps,Dredge Pump Ash Slurry Pumps,Submersible Slurry Dredging Pumps,WN Series Dredge Slurry Pump,Dredge Ash Slurry Pump

Shijiazhuang Soarho Machinary Co.,Ltd , http://www.xhslurrypump.com

Posted on